Siren Gas Detector 

CE approved ; Welcome OEM

(a) Our Siren Gas Detector complies with European Standard   EN50054;as does our Electrical Apparatus for the Detection Measurement of Combustible Gases and General Requirements and Test Methods.

(b) Our Siren Gas Detector complies with UL Standard 1484 for residential gas detectors. And meets RoHS Standards.

  

 ↑ Click this icon to see Gas Detector photos

Our Siren Gas Detector is designed to detect flammable gasnatural gas (methane) and LP-gas (propane) from ANY source of combustion. It is NOT designed to detect smoke, fire or any other gas.

Siren Gas Model G-110 detector plugs into an electrical power outlet of AC110V~120V50~60Hz.

Siren Gas Model G-220 detector plugs into an electrical power outlet of AC 220V~240V 50~60Hz

 
CORRECT MOUNTING POSITION:

Our Siren Gas Detector size 14.5 cm L x 8 cm W x 4 cm H

Mount gas detector on the wall. Mount within 1 foot, measured vertically from the highest point of the ceiling, or within 1 foot above the floor, and measured horizontally between 3 feet to 10 feet. Depending on which flammable gas will be detected. This gas detector is designed for use inside a single family home or apartment.


1 foot



1 foot
  Ceiling
 
Natural gas (methane)
Mounting position
 
 
 
LP-gas (propane)
Mounting position
 
Floor
 
3 feet
Detector
Position

10 feet
Detector
Position

Gas Appliances
Gas Water Heater
 
Gas stove
Gas Furnace


Whenever the gas detector detects flammable gas up to 25% of lower explosive limits, the red light and audio alarm sound will automatically turn on in 5 seconds. When audio alarm sounds, in this event you must at once follow the regular gas alarm procedure. If the gas level reaches 10% of lower explosive limits, the red light and audio alarm sound will automatically turn on in 20 seconds. If the gas level reduces to 5% of lower explosive limits, the red light and audio alarm sound will automatically turn off in 5 seconds.

 Exhaust fan function:

When gas reaches alarm level, the alarm circuitry will turn on the exhaust fan (Relay). When gas reduces to safety level, the alarm circuitry will turn off the exhaust fan (Relay) and warning sound in 5 seconds.

Gas
Lower explosive limits
Alarm will activate before
Alarm will activate before
Natural gas (methane) 3.8% by volume in air 25% of lower explosive limits 0.95% by volume in air
LP-gas (propane) 2.1% by volume in air 25% of lower explosive limits 0.52% by volume in air

 

Relay/Fan and Alarm will activate in 5 seconds Relay/Fan and Alarm will activate in 20 seconds
0.95% by volume of Natural gas (methane) in air 0.2% by volume of Natural gas (methane) in air
0.52% by volume of LP-gas (propane) in air 0.1% by volume of LP-gas (propane) in air

 



 
Copyright©2008 Chia Wei Electric Co., Ltd. All rights reserved
No. 27, Lane 24, Da-Lian North Street., Taichung, Taiwan 406
TEL:886-4-2292-1202∣FAX:886-4-2291-8645∣ Skype:ozonehelps_nancy
helps@ozonehelps.com∣ozonehelps@gmail.com